| An ideal mains source
in cars, pickups, Emergency vehicles, heavy duty trucks, industrial
locations such as offices and warehouses, caravans, boats etc. Can
be used for most types of electronic equipment.
- Compact size.
- Built-in alarm.
- Short circuit proof.
- Terminal Block (screw terminals).
- Available in 12 V and 24 V voltage versions.
- EU or UK output socket.
Technical specifications may vary, please contact
us for more information.
| Technical specifications: 12V
version |
| Input Voltage |
10 - 15 VDC |
| Output voltage (modified sinus) |
230 VAC +5/-10% (50 Hz) |
Output Power
Continuous
Intermittent |
600 W
1000 W |
| No load current |
<0,65 A |
| Efficiency (at full load) |
85 - 90% |
| Low Battery Alarm |
10,7 V |
| Low Battery Shut-Down |
10 V |
| Electrical safety standard |
EN 60950 |
EMC standards
Emission
Immunity |
EN 50081-1
EN 50082-1 |
| Protection |
Input low voltage, input over voltage,
low battery alarm, over temperature,
overload protection and short circuit proof. |
| DC terminals |
Terminal Block (screw terminals) |
| Dimensions (LxWxH) |
280 x 240 x 80 mm |
| Weight |
2.45 kg |
| Technical specifications:
24V version |
| Input Voltage |
20 - 30 VDC |
| Output voltage (modified sinus) |
230 VAC +5/-10% (50 Hz) |
Output Power
Continuous
Intermittent |
600 W
1000 W |
| No load current |
<0,4 A |
| Efficiency (at full load) |
85 - 90% |
| Low Battery Alarm |
21 V |
| Low Battery Shut-Down |
20 V |
| Electrical safety standard |
EN 60950 |
EMC standards
Emission
Immunity |
EN 50081-1
EN 50082-1 |
| Protection |
Input low voltage, input over voltage,
low battery alarm, over temperature,
overload protection and short circuit proof. |
| DC terminals |
Terminal Block (screw terminals) |
| Dimensions (LxWxH) |
280 x 240 x 80 mm |
| Weight |